106693-1570 ZEXEL INJECTION-PUMP ASSEMBLY Calibration Data 1066931570 1156018030


106693-1570 INJECTION-PUMP ASSEMBLY
Rating:
75
Buy INJECTION-PUMP ASSEMBLY 106693-1570 zexel genuine, new aftermarket engine parts with delivery

Information injection-pump assembly

ZEXEL 106693-1570 1066931570
ISUZU 1156018030 1156018030

Cross reference number

ZEXEL 106693-1570 1066931570
ISUZU 1156018030 1156018030


Zexel num
Bosch num
Firm num
Name
106693-1570 
106693-1571 
 
1156018030  ISUZU
INJECTION-PUMP ASSEMBLY
6RB1 *

Calibration Data:

Adjustment conditions
Test oil
1404 Test oil
  ISO4113 or {SAEJ967d}
Test oil temperature degC   40 40 45
Nozzle and nozzle holder   105780-8140
Bosch type code   EF8511/9A
Nozzle   105780-0000
Bosch type code   DN12SD12T
Nozzle holder   105780-2080
Bosch type code   EF8511/9
Opening pressure MPa   17.2
Opening pressure kgf/cm2   175
Injection pipe
Outer diameter - inner diameter - length (mm)
mm   8-3-600
Overflow valve   134424-1920
Overflow valve opening pressure kPa   127 107 147
Overflow valve opening pressure kgf/cm2   1.3 1.1 1.5
Tester oil delivery pressure kPa   157 157 157
Tester oil delivery pressure kgf/cm2   1.6 1.6 1.6
Direction of rotation (viewed from drive side)
Right
  R
Injection timing adjustment
Direction of rotation (viewed from drive side)
Right
  R
Injection order   1-4-2-6- 3-5
Pre-stroke mm   3 2.95 3.05
Beginning of injection position
Drive side
  NO.1
Difference between angles 1
Cal 1-4
deg.   60 59.5 60.5
Difference between angles 2
Cyl.1-2
deg.   120 119.5 120.5
Difference between angles 3
Cal 1-6
deg.   180 179.5 180.5
Difference between angles 4
Cal 1-3
deg.   240 239.5 240.5
Difference between angles 5
Cal 1-5
deg.   300 299.5 300.5
Injection quantity adjustment
Adjusting point   A
Rack position   8.9
Pump speed r/min   650 650 650
Average injection quantity mm3/st.   133.9 131.9 135.9
Max. variation between cylinders %   0 -3 3
Basic   *
Fixing the lever   *
Injection quantity adjustment_02
Adjusting point   B
Rack position   5.3+-0.5
Pump speed r/min   225 225 225
Average injection quantity mm3/st.   12.6 9.4 15.8
Max. variation between cylinders %   0 -13 13
Fixing the rack   *
Injection quantity adjustment_03
Adjusting point   D
Rack position   7.3
Pump speed r/min   650 650 650
Average injection quantity mm3/st.   89 85 93
Max. variation between cylinders %   0 -3 3
Fixing the lever   *
Remarks
At absolute pressure 61.3 kPa {460 mmHg}
 
Timer adjustment
Pump speed r/min   500
Advance angle deg.   0.3
Timer adjustment_02
Pump speed r/min   700
Advance angle deg.   1 0.1 1
Timer adjustment_03
Pump speed r/min   900
Advance angle deg.   1.2 0.7 1.7
Timer adjustment_04
Pump speed r/min   1100
Advance angle deg.   2 1.5 2.5
Remarks
Finish
 

Test data Ex:

Governor adjustment

Test data 106693-1570
N:Pump speed R:Rack position (mm) (1)Lever ratio: RT (2)Target shim dimension: TH (3)Damper spring setting: DL (4)Excess fuel setting for starting: SXL (5)Aneroid compensator absolute pressure: at P1 (6)Rack difference between N = N1 and N = N2 (7)Main spring setting (8)Set idle.
----------
RT=1 TH=2.1mm DL=3.7-0.5mm SXL=9.2+0.2mm P1=61.3+-0.7kPa(460+-5mmHg) N1=1100r/min N2=650r/min
----------

Speed control lever angle

Test data 106693-1570
F:Full speed I:Idle (1)Stopper bolt setting
----------

----------
a=(10deg)+-5deg b=1.5deg+-5deg

0000000901

Test data 106693-1570
F:Full load I:Idle (1)Stopper bolt setting (2)Attach the return spring to the upper hole and adjust.
----------

----------
a=30deg+-5deg b=30deg+-3deg

Stop lever angle

Test data 106693-1570
N:Pump normal S:Stop the pump.
----------

----------
a=32deg+-5deg b=64deg+-5deg

0000001501 ACS

Test data 106693-1570
(A) Set screw (B) Push rod 1 1. Aneroid compensator unit adjustment (1)Screw in (A) to obtain L1. 2. Adjustment following governor installation (1)Set the speed of the pump to N1 r/min and fix the control lever at the full set position. (2)Screw in the aneroid compensator to obtain the performance shown in the graph above.
----------
N1=650r/min L1=(0.1~0.5)mm
----------
R1=8.9mm R2=7.3mm P1=(94.6)kPa((710)mmHg) P2=61.3+-0.7kPa(460+-5mmHg) Q1=133.9+-2cm3/1000st Q2=(89)+-2cm3/1000st

Timing setting

Test data 106693-1570
(1)Pump vertical direction (2)Position of timer's threaded hole at No 1 cylinder's beginning of injection (3)B.T.D.C.: aa (4)-
----------
aa=21deg
----------
a=(70deg)




Have questions with 106693-1570?





Group cross 106693-1570 ZEXEL

Isuzu 

 
1156016930 
INJECTION-PUMP ASSEMBLY
6RA1
 
1156017060 
INJECTION-PUMP ASSEMBLY
6RA1
 
1156017070 
INJECTION-PUMP ASSEMBLY
6RA1
 
1156017110 
INJECTION-PUMP ASSEMBLY
6RA1
 
1156017120 
INJECTION-PUMP ASSEMBLY
6RA1
 
1156018110 
INJECTION-PUMP ASSEMBLY
6QA2
 
1156018111 
INJECTION-PUMP ASSEMBLY
6QA2
9 400 617 908 
1156018112 
INJECTION-PUMP ASSEMBLY
6QA2
 
1156018330 
INJECTION-PUMP ASSEMBLY
6RA1
9 400 617 909 
1156018331 
INJECTION-PUMP ASSEMBLY
6RA1
106693-1570  

106693-1571 
 
1156018030 
INJECTION-PUMP ASSEMBLY
6RB1
 
1156018031 
INJECTION-PUMP ASSEMBLY
6RB1
 
1156018430 
INJECTION-PUMP ASSEMBLY
6RB2
 
1156018431 
INJECTION-PUMP ASSEMBLY
6RB2
 
1156018432 
INJECTION-PUMP ASSEMBLY
6RB2
 
1156018440 
INJECTION-PUMP ASSEMBLY
6RB2
 
1156018441 
INJECTION-PUMP ASSEMBLY
6RB2
 
1156018442 
INJECTION-PUMP ASSEMBLY
6RB2
Back to top