Rating:
Information injection-pump assembly
BOSCH
9 400 613 994
9400613994
ZEXEL
101402-9070
1014029070
YANMAR
12741051010
12741051010
Service parts 101402-9070 INJECTION-PUMP ASSEMBLY:
1.
_
6.
COUPLING PLATE
7.
COUPLING PLATE
8.
_
9.
_
11.
Nozzle and Holder
12.
Open Pre:MPa(Kqf/cm2)
19.6{200}
15.
NOZZLE SET
Cross reference number
BOSCH
9 400 613 994
9400613994
ZEXEL
101402-9070
1014029070
YANMAR
12741051010
12741051010
Zexel num
Bosch num
Firm num
Name
101402-9070
9 400 613 994
12741051010 YANMAR
INJECTION-PUMP ASSEMBLY
4CH K 14BC INJECTION PUMP ASSY PE4A,5A, PE
4CH K 14BC INJECTION PUMP ASSY PE4A,5A, PE
Calibration Data:
Adjustment conditions
Test oil
1404 Test oil ISO4113 or {SAEJ967d}
1404 Test oil ISO4113 or {SAEJ967d}
Test oil temperature
degC
40
40
45
Nozzle and nozzle holder
105780-8140
Bosch type code
EF8511/9A
Nozzle
105780-0000
Bosch type code
DN12SD12T
Nozzle holder
105780-2080
Bosch type code
EF8511/9
Opening pressure
MPa
17.2
Opening pressure
kgf/cm2
175
Injection pipe
Outer diameter - inner diameter - length (mm) mm 6-2-600
Outer diameter - inner diameter - length (mm) mm 6-2-600
Overflow valve
131424-0220
Overflow valve opening pressure
kPa
157
123
191
Overflow valve opening pressure
kgf/cm2
1.6
1.25
1.95
Tester oil delivery pressure
kPa
157
157
157
Tester oil delivery pressure
kgf/cm2
1.6
1.6
1.6
Direction of rotation (viewed from drive side)
Right R
Right R
Injection timing adjustment
Direction of rotation (viewed from drive side)
Right R
Right R
Injection order
1-2-4-3
Pre-stroke
mm
3
2.95
3.05
Beginning of injection position
Drive side NO.1
Drive side NO.1
Difference between angles 1
Cyl.1-2 deg. 90 89.5 90.5
Cyl.1-2 deg. 90 89.5 90.5
Difference between angles 2
Cal 1-4 deg. 180 179.5 180.5
Cal 1-4 deg. 180 179.5 180.5
Difference between angles 3
Cal 1-3 deg. 270 269.5 270.5
Cal 1-3 deg. 270 269.5 270.5
Injection quantity adjustment
Adjusting point
A
Rack position
9.5
Pump speed
r/min
1300
1300
1300
Each cylinder's injection qty
mm3/st.
57.1
55.6
58.6
Basic
*
Fixing the rack
*
Injection quantity adjustment_02
Adjusting point
B
Rack position
6.3+-0.5
Pump speed
r/min
200
200
200
Each cylinder's injection qty
mm3/st.
16
15
17
Fixing the rack
*
Injection quantity adjustment_03
Adjusting point
C
Rack position
-
Pump speed
r/min
100
100
100
Each cylinder's injection qty
mm3/st.
72
72
100
Fixing the lever
*
Injection quantity adjustment_04
Adjusting point
D
Rack position
4.3
Pump speed
r/min
1300
1300
1300
Each cylinder's injection qty
mm3/st.
8.5
6.5
10.5
Fixing the rack
*
Test data Ex:
Governor adjustment
N:Pump speed
R:Rack position (mm)
(1)Target notch: K
(2)RACK LIMIT: RAL
----------
K=3 RAL=11.6+0.2mm
----------
----------
K=3 RAL=11.6+0.2mm
----------
Speed control lever angle
F:Full speed
I:Idle
S:Stop
----------
----------
a=10deg+-5deg b=29deg+-5deg c=32deg+-3deg
----------
----------
a=10deg+-5deg b=29deg+-5deg c=32deg+-3deg
Stop lever angle
N:Pump normal
S:Stop the pump.
----------
----------
a=(20deg) b=(33deg)
----------
----------
a=(20deg) b=(33deg)
Have questions with 101402-9070?
Group cross 101402-9070 ZEXEL
Yanmar
101402-9070
9 400 613 994
12741051010
INJECTION-PUMP ASSEMBLY
4CH
4CH