Rating:
Information
ZEXEL
101652-2060
1016522060
HINO
6071110640
6071110640
Cross reference number
ZEXEL
101652-2060
1016522060
HINO
6071110640
6071110640
Zexel num | Bosch num | Firm num | Firm | Name |
101652-2060
101652-2080 |
6071110640 | HINO | EC100A * |
Calibration Data:
Adjustment conditions Test oil ISO4113 or {SAEJ967d}
1404 Test oil
Test oil temperature
degC
40
40
45
Nozzle
105780-0020
Bosch type code
DN4SD24T
Nozzle holder
105031-2010
Bosch type code
KB56SD273
Opening pressure
MPa
11.8
Opening pressure
kgf/cm2
120
Injection pipe
mm
6-2-600
Outer diameter - inner diameter - length (mm)
Outer diameter - inner diameter - length (mm)
Overflow valve
132424-0620
Overflow valve opening pressure
kPa
157
123
191
Overflow valve opening pressure
kgf/cm2
1.6
1.25
1.95
Tester oil delivery pressure
kPa
157
157
157
Tester oil delivery pressure
kgf/cm2
1.6
1.6
1.6
Direction of rotation (viewed from drive side)
R
Right
Right
Injection timing adjustment Direction of rotation (viewed from drive side) R
Right
Injection order
1-4-2-6-
3-5
Pre-stroke
mm
1.95
1.9
2
Beginning of injection position
NO.1
Drive side
Drive side
Difference between angles 1
deg.
60
59.5
60.5
Cal 1-4
Cal 1-4
Difference between angles 2
deg.
120
119.5
120.5
Cyl.1-2
Cyl.1-2
Difference between angles 3
deg.
180
179.5
180.5
Cal 1-6
Cal 1-6
Difference between angles 4
deg.
240
239.5
240.5
Cal 1-3
Cal 1-3
Difference between angles 5
deg.
300
299.5
300.5
Cal 1-5
Cal 1-5
Injection quantity adjustment Adjusting point A
Rack position
11.1
Pump speed
r/min
1050
1050
1050
Average injection quantity
mm3/st.
56.2
53.2
59.2
Max. variation between cylinders
%
0
-4
4
Fixing the rack
*
Injection quantity adjustment_02 Adjusting point B
Rack position
11.9
Pump speed
r/min
600
600
600
Average injection quantity
mm3/st.
56.8
55.8
57.8
Max. variation between cylinders
%
0
-3
3
Basic
*
Fixing the lever
*
Injection quantity adjustment_03 Adjusting point C
Rack position
7.2+-0.5
Pump speed
r/min
300
300
300
Average injection quantity
mm3/st.
16
13.9
18.1
Max. variation between cylinders
%
0
-13
13
Fixing the rack
*
Test data Ex:
Governor adjustment
N:Pump speed
R:Rack position (mm)
(1)Target notch: K
----------
K=10
----------
Speed control lever angle
F:Full speed
I:Idle
S:Stop
----------
----------
a=5deg+-5deg b=32deg+-3deg c=28.5deg+-3deg